What is the inquiry and reporting mechanism for power statistics?

Last Updated on2023-11-22 03:37:07
1. The hardware does not actively (or rarely) report current, voltage, and power data. 2. When you open the app's power statistics panel, the panel sends query commands at 5s intervals. The hardware reports the power statistics to the cloud after receiving a query command. When you exit the app's power statistics panel, the panel stops sending query commands and the hardware no longer actively (or rarely) reports data. 3. The hardware passively reports current, voltage, and power data and actively reports increased power consumption data at intervals of 5 to 30 minutes. Note: * Conditions for querying and reporting power data: Panel upgraded (a version available for the public panel of a single socket) + app version 3.8.0 or later + firmware baseline 5.42 or later * Power statistics of plug-and-play firmware: Considering the diversity of customer panels and app versions, the firmware uses an active reporting mechanism by default. If it receives a query command from the panel, it will switch to the reporting upon query mechanism. * If the querying protocol is supported for all queried data, the firmware reports the current, voltage, and power data at intervals of 10 to 30 minutes when the panel does not send query commands.