What is the logic for a socket to report power statistics?

Last Updated on2023-11-22 06:39:34
1. Parameter reporting mechanism for electricity:
Conditions: Current: None Voltage: Rate of change <2% Power: Rate of change <20%
Result: The 30S collection interval is judged, and the above conditions are met, and the interval is 1h and reported
If one of the two judgments of voltage or power exceeds the appeal condition, the current, voltage and power will be reported together;
After triggering the report, the next acquisition judgment interval is changed to 5s. If the change rate is within the range, the acquisition will continue for 30s.
Note: In order to reduce the pressure on the cloud, the reporting of current/elegant/power must follow the reporting logic. In order not to affect the user experience, when the user opens the panel, the panel sends a query command. At this time, the current/elegant/power is reported once every 5s. When viewing, the data can still change in real time.
2.Electricity report distinguishes between incremental report and full report:
In the current public version, devices that rely on the gateway to connect to the cloud adopt full reporting logic, such as Zigbee and Bluetooth devices adopt full reporting logic; devices that do not need to rely on the gateway to connect to the cloud adopt incremental reporting logic, such as Wi-Fi devices adopt incremental reporting.
Incremental reporting: The time is 10-30 minutes, and the power increment is ≥ 0.1 degrees, report; If the time is more than 30 minutes, and the power increment is ≥ 0.001 degrees, report.
Full report: report the total electricity every time the electricity increases by 0.02kwh.